What should I do if the signal transmission of the conductive slip ring is unstable?
site: home newsindustry

What should I do if the signal transmission of the conductive slip ring is unstable?

We all know that conductive slip rings are electrical products that can rotate and transmit various media. We have also encountered many problems when using conductive slip rings. One is that the signal transmitted by the conductive slip ring is always unstable, etc. In fact, these problems are small problems we encountered when using the conductive slip ring. Today, the editor of JARCH conductive slip ring will tell you about the conductive slip ring. What should I do if the transmitted signal is unstable and is always disturbed.

图片

The signal transmission of the conductive slip ring is unstable. We first need to determine whether the existence of the conductive slip ring itself causes the unstable signal transmission. The reason of the conductive slip ring itself causes unstable signal transmission, such as excessive wear of the internal brush wire, the internal contact material cannot transmit the signal, and the signal transmitted to the slip ring design is different from the actual transmitted signal. For example, the design of the conductive slip ring The ring transmits an ordinary temperature sensing signal line, but the actual installation requires a conductive slip ring to transmit the network signal. This situation will also cause unstable signal transmission, and the conductive slip ring is caused by an internal short circuit. Internal signal interference will also lead to unstable signal transmission of the conductive slip ring. The above points are the factors that may cause the unstable signal transmission of the conductive slip ring itself. We only need to eliminate them one by one.

Then a use environment outside the conductive slip ring will also cause unstable signal transmission of the conductive slip ring. The first is that there are devices such as servo encoders that can generate interference signals around the conductive slip ring. Such devices will emit signal interference signals, resulting in The signal transmission of the conductive slip ring is unstable. The second is that the external use environment of the conductive slip ring is inconsistent with the conductive slip ring at the time of design. For example, the conductive slip ring is not designed with high temperature, waterproof and other special environments, but when the conductive slip ring is actually used, it is at high temperature. , in a high humidity environment. Such a situation will also lead to the failure of the conductive slip ring, which may cause instability in the transmission of the conductive slip ring.

Therefore, in order to prevent the purchased conductive slip ring from being unusable, we must determine the use of the conductive slip ring when purchasing the conductive slip ring, and design the conductive slip ring according to the specific use of the conductive slip ring. For example, if there is an interference source around the conductive slip ring, then we need to shield the conductive slip ring. For example, if our conductive slip ring is used in a high temperature environment, then we need to perform high temperature resistance treatment on the conductive slip ring. The particularity of the conductive slip ring determines that more than 90% of the conductive slip ring needs to be customized. Different equipment, different technical requirements, and different use environments need to match the conductive slip rings of different specifications. Who don't understand conductive slip rings can directly contact JARCH conductive slip rings, and find JARCH for slip rings, synonymous with durability!


This month from: http://jiachijidian.cn7.iswweb.cn/ JARCH conductive slip ring Please indicate the source